GDBT Series Transformer Test Bench
GDBT Transformer test system can conduct all routine tests for transformers, including No-load and load test, Induced voltage test, Power frequency withstand voltage test, partial discharge test, DC resistance test, turns ratio test, temperature rising test etc.
-
GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV
There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation. The dielectric strength of insulating oil is a mandatory routine test. In order to meet the needs of the market, our company developed and produced a series of dielectric oil dielectric strength testers according to the national standard GB/T507-2002(IEC156), the standard DL429.9-91 and the latest power industry standard DL/T846.7-2004. This instrument takes the single-chip microcomputer as the core, realizes all the automation of the test, has high measurement precision, greatly improves the work efficiency, and greatly reduces the labor intensity of the staff. At the same time, the instrument has a compact appearance and is convenient to carry.
-
GDZRC-100U Transformer DC Winding Resistance Tester
Transformer DC winding resistance is a required test item for the factory test, installation, overhaul, change of tap switch, handover test and preventive test of power department.
-
GDB-D Transformer Turn Ratio Tester
GDB-D Transformer turn ratio tester is designed for three phases transformer in power system and especially for Z type winding transformer and other transformers with relatively large no-load current.
-
GDZRC-10U DC Winding Resistance Tester
The measurement of DC transformer resistance is a mandatory test item in transformer manufacturing of semi-finished products, finished products factory test, installation, handover test and preventive test of power department, which can effectively find the manufacturing defects of transformer coil material selection, welding, loose connection parts, missing strands, broken wires and other hidden dangers after operation.
GDZRC-10U DC Winding resistance tester is a rapid test equipment for measuring the DC resistance of transformers, transformers, generators and motors, and it is a replacement product of single and double arm Bridges.
-
GD6400A Capacitance and Dissipation Factor Tester
GD6400A measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is mainly for testing big capacity HV capacitive equipment such as HV motor, HV bushing and HV power cable, by using external HV power testing source.
It includes handheld terminal and test main unit. 2.4G wireless communication mode is used between handheld terminal and test main unit.
-
GDBR-P Transformer Load No-load and Capacity Tester
Measure transformer No-load current, No-load loss, short circuit voltage, short circuit loss and capacity.
Three meters testing methods. -
GDB-II Transformer Turns Ratio Tester
According to IEC and relevant national standards, the transformer ratio test is a must-do item during the production, user handover, and overhaul test of power transformers. This can effectively supervise the quality of the transformer products during delivery and use, and prevent short circuits, open circuit, wrong connection between transformer turns, and internal failure or contact failure of the regulator switch.
For this reason, the ratio tester GDB-II developed and produced by our company makes the operation easier, complete functions, stable and reliable data, and greatly improves the test speed according to the user’s on-site use requirements on the original basis. It meets the needs of various large, medium, and small oil transformer ratio tests.
-
GDB-H Handheld Automatic Transformer Turns Ratio Tester
It can accurately measure turns ratio, group and phase angle, which is suitable for all kinds of transformers such as Z type transformers, rectifier transformers, electric furnace transformers, phase-shifting transformers, traction transformers, scott and invert-scott transformers.
-
GD6800 Capacitance and Dissipation Factor Tester
GD6800 is a fully automatic 10kV insulation power factor/dissipation factor (tan∂) tester designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arresters and rotating machinery.
-
GDOT-3B 100kV Three Cups Insulation Oil Breakdown Voltage (BDV) Tester
In the power system and factories, mines, enterprises have a large number of electrical equipment, its internal insulation are oil-filled insulation. The dielectric strength test of the insulating oil is a routine test must be measured.
In order to adapt to the needs of the rapid development of the power industry, the new version GDOT-3B Insulation oil BDV tester increase the standards and methods of selection and other content, simplify the user’s operation, to facilitate the application of the user for different conditions of use. This product is based on the new test protocol DL/T 596-2005 and the corresponding national standard GB/T 507-2002 and DL/T 429.9-91 design and manufacture, the use of micro-single-chip computer control, electromechanical integration of all automation, high measurement accuracy, greatly improving the efficiency of the work, but also greatly reduces the staff’s labor intensity.
-
GDB-IV Three Phase Transformer Turns Ratio Tester
The internal power module in the tester generates the three-phase power or two-phase power, which is output to the high voltage side of the transformer. Then the high voltage and low voltage are sampled at the same time. Finally, the group, ratio, error, and phase difference are calculated.